Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 98(41): e17525, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31593126

RESUMO

To assess the intra-individual and inter-individuals biological variation and the effect of aging on lymphocyte T-cells subsets.We assessed lymphocyte phenotypes (CD3, CD4, and CD8 T-cells) in 89 HIV-1-infected and 88 uninfected white non-Hispanic men every 6 months, to examine the biological variation for those measurements, and the average change in lymphocyte phenotype over 34 years.The markers showed significant intra-individuality in HIV-infected and uninfected individuals with index of individuality of <1.4. No mean changes were seen over the 34 years, with the exception of percentage CD4T-cells in HIV-uninfected individuals.In the pre-HAART era, HIV-infected individuals experienced an increase in mean absolute CD3 T-cell numbers (11.21 cells/µL, P = 0.02) and absolute CD8 T-cell numbers (34.57 cell/µl, P < .001), and in the percentage of CD8 T-cells (1.45%, P < .001) per year and a significant decrease in mean absolute CD4 T-cell numbers (23.68 cells/µl, P < .001) and in the percentage of CD4 T-cells (1.49%, P < .001) per year.In the post-HAART era, no changes in mean levels were observed in absolute CD3 T-cell count (P = .15) or percentage (P = .99). Significant decreases were seen in mean count (8.56 cells/µl, P < .001) and percentage (0.59%, P < .001) of CD8 T-cells, and increases in mean absolute count (10.72 cells/µl, P < .001) and percentage (0.47%, P < .001) of CD4 T-cells.With the exception of CD4 (%), no average changes per year were seen in lymphocyte phenotype of HIV-uninfected men. The results of coefficients of variation of intra and inter-individuals of this study can be useful for HIV-1 infection monitoring and in addition the observation could be a useful guide for intra- and inter-individual coefficient variations, and establishing quality goal studies of different blood biomarkers in healthy and other diseases.


Assuntos
Síndrome da Imunodeficiência Adquirida/imunologia , Variação Biológica da População/imunologia , Infecções por HIV/imunologia , Subpopulações de Linfócitos T/imunologia , Síndrome da Imunodeficiência Adquirida/etnologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia Antirretroviral de Alta Atividade/estatística & dados numéricos , Variação Biológica da População/etnologia , Biomarcadores/sangue , Complexo CD3/efeitos dos fármacos , Complexo CD3/imunologia , Complexo CD3/metabolismo , Antígenos CD4/imunologia , Antígenos CD4/metabolismo , Linfócitos T CD8-Positivos/efeitos dos fármacos , Linfócitos T CD8-Positivos/imunologia , Linfócitos T CD8-Positivos/metabolismo , Senescência Celular/imunologia , Estudos de Coortes , Infecções por HIV/tratamento farmacológico , Infecções por HIV/metabolismo , Humanos , Los Angeles/epidemiologia , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Fenótipo , Subpopulações de Linfócitos T/metabolismo
2.
Cytometry B Clin Cytom ; 78(3): 194-200, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-19813263

RESUMO

BACKGROUND: Previous studies have reported that the adoption of a single-platform flow cytometry cell counting method resulted in lower interlaboratory variation in absolute T cell counts as compared to predicate dual-platform flow cytometry methods which incorporate independent automated lymphocyte counts (Schnizlein-Bick et al., Clin Diagn Lab Immunol 2000;7:336-343; Reimann et al., Clin Diagn Lab Immunol 2000;7:344-351). In the present study, we asked whether use of a single-platform method could reduce variation in absolute cell counts across the laboratories in the Multicenter AIDS Cohort Study (MACS) (n = 4), as suggested by the studies cited. METHODS: Identical study samples were shipped overnight to the MACS laboratories either by the National Institute of Allergy and Infectious Diseases, Division of AIDS Immunology Quality Assessment (NIAID- IQA) proficiency-testing program (n = 14), or by the Los Angeles site of the MACS (n = 10). For each sample, two tubes of blood were received; one was used for an automated complete blood count and differential, and the other for flow cytometry. The latter was performed using both our current dual-platform method (three-color CD45 gating and automated hematology) and the single-platform method (with TruCOUNT beads to generate the absolute counts). RESULTS: The median percent coefficients of variation (%CVs) for the dual-platform and single-platform methods were 6.6 and 9.9, respectively, for CD4 T cell counts, and 5.9 and 8.5, respectively, for CD8 T cell counts (n = 24). These differences were not statistically significant. The differences in absolute T-cell counts between the MACS sites and the median of all laboratories participating in the NIAID-IQA were smaller for the dual-platform than for single-platform absolute count method. CONCLUSION: In contrast to previous reports, we did not observe lower interlaboratory variation across the MACS sites for single-platform absolute lymphocyte subset counting relative to dual-platform methods. This result may be at least partly explained by the lower interlaboratory variation with the optimized dual-platform method in this study relative to the previous reports.


Assuntos
Citometria de Fluxo/métodos , Laboratórios , Contagem de Linfócitos/métodos , Estudos de Coortes , Citometria de Fluxo/instrumentação , Citometria de Fluxo/normas , Humanos , Laboratórios/normas , Contagem de Linfócitos/normas , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA